Operational Inspection - every 1-3 months
This should be carried by the Operator every 1-3 months.
Examples of visual checks and operational inspection are cleanliness, condition of ground and walkway surface, sharp edges, missing components, excessive wear [of any elements and/or moving parts] and the structural integrity of the whole system specifically including whole steel cable elements.
Specifically steel cables, wire grips and ferrules, shackles, thimbles, rigging screws, steel wire wear or animal damage of ropes or netting, any change in the nature/appearance of timbers, any vandalism or tampering, damaged branches, low hanging branches, any unexpected or inappropriate activity, rubbish, trip-hazard branches or undergrowth. An appropriately trained person will normally do this.